THANKS for the support. I pulled it this morning and sure enough there was a cobweb there in the orifice at the outlet of the valve.
It was quick and easy.
Appreciate your assitance.
Search found 3 matches
- Sat Oct 13, 2012 12:03 pm
- Forum: Coleman Service & Repair
- Topic: How to check flame sensor...DGAA070BDTA
- Replies: 5
- Views: 7747
- Tue Oct 09, 2012 7:40 am
- Forum: Coleman Service & Repair
- Topic: How to check flame sensor...DGAA070BDTA
- Replies: 5
- Views: 7747
Re: How to check flame sensor...DGAA070BDTA
Thanks. That means I will have to pull the gas valve, right?
- Sun Oct 07, 2012 11:45 am
- Forum: Coleman Service & Repair
- Topic: How to check flame sensor...DGAA070BDTA
- Replies: 5
- Views: 7747
How to check flame sensor...DGAA070BDTA
Greetings, I just love it when I find a new place for my questions. Our furnace is just four years old and worked fine in March. Today the flame will not light. It goes through 2-3 cycles--pilot lights, but burners will not. We tried the T-stat bypass and same results. Green Light flashes once. How ...