Search found 17 matches
- Mon Jan 25, 2010 9:57 pm
- Forum: Nordyne Service & Repair
- Topic: Intertherm Gasket?
- Replies: 1
- Views: 1364
Intertherm Gasket?
Intertherm model #1M1MB 07A BW Serial # 981001373. I need gasket where the gas valve goes but don't see any on your site. I am also in bad need of an ignitor bt need gasket too want to order tem both at the same time.
- Sat Feb 28, 2009 10:48 am
- Forum: Nordyne Service & Repair
- Topic: Ignition question
- Replies: 15
- Views: 6504
RE: Ignition question
Robert, The clicking is the gas valve itself. I just replaced the ignitor this winter. As for the amp draw I'm not sure what you mean. The gas valve has 26.61 vac and the ignitor has 121.1 vac. Now the good news is that starting late last night it started working fine and has continued to do so. I h...
- Fri Feb 27, 2009 5:55 pm
- Forum: Nordyne Service & Repair
- Topic: Ignition question
- Replies: 15
- Views: 6504
RE: Ignition question
Robert, Installed the control board today but no change. I have noticed that it was starting to click more before I put the control board on. When it clicks the first time it actually ignites and continues to click off and on very quickly before staying lit. What are the symptoms when the gas valve ...
- Mon Feb 23, 2009 8:37 pm
- Forum: Nordyne Service & Repair
- Topic: Ignition question
- Replies: 15
- Views: 6504
RE: Ignition question
Robert,
Everything vac look good other than to the gas valve. It is clicking in the circuit board and the gas valve 3 or 4 times before lighting. It sounds to me that Im going to need ordering info.
Everything vac look good other than to the gas valve. It is clicking in the circuit board and the gas valve 3 or 4 times before lighting. It sounds to me that Im going to need ordering info.
- Mon Feb 23, 2009 8:13 pm
- Forum: Nordyne Service & Repair
- Topic: Ignition question
- Replies: 15
- Views: 6504
RE: Ignition question
I you are talkig about the two terminals marked c and w they have a little more than 26 vac and when it starts clicking it does drop some but never under 24 vac.
- Mon Feb 23, 2009 7:26 pm
- Forum: Nordyne Service & Repair
- Topic: Ignition question
- Replies: 15
- Views: 6504
RE: Ignition question
Robert,
When I place the meter on the gas valve pins at the circuit board the vac fluctuates like I said before.
When I place the meter on the gas valve pins at the circuit board the vac fluctuates like I said before.
- Mon Feb 23, 2009 5:16 pm
- Forum: Nordyne Service & Repair
- Topic: Ignition question
- Replies: 15
- Views: 6504
RE: Ignition question
Robert,
The ignitor seems to hold around 120.2 to 120.4 volts but doesn't fluctuate when the clicking occurs. When I place the meter on the gas valve terminals the readings fluctuate so fast that I can't keep up with reading them.
The ignitor seems to hold around 120.2 to 120.4 volts but doesn't fluctuate when the clicking occurs. When I place the meter on the gas valve terminals the readings fluctuate so fast that I can't keep up with reading them.
- Sat Feb 21, 2009 10:11 am
- Forum: Nordyne Service & Repair
- Topic: Ignition question
- Replies: 15
- Views: 6504
RE: Ignition question
I checked ignitor at connector and it stayed at 118.5 most of the time and then jumped to 120.8 and stayed for close to 30 seconds but not any more than 30.
- Fri Feb 20, 2009 7:43 am
- Forum: Nordyne Service & Repair
- Topic: Ignition question
- Replies: 15
- Views: 6504
Ignition question
Intertherm Model# M1MB 07A BW.
When it starts to ignite it clicks of and on 2,3 and sometimes 4 times really fast before it finally stays lit. What would cause this?
When it starts to ignite it clicks of and on 2,3 and sometimes 4 times really fast before it finally stays lit. What would cause this?
- Thu Jan 29, 2009 8:27 pm
- Forum: All Other HVAC Questions
- Topic: Thermostat heat anticipator setting?
- Replies: 3
- Views: 5090
RE: Thermostat heat anticipator setting?
Intertherm Gas furnace and Intertherm thermostat.
- Fri Jan 23, 2009 7:03 am
- Forum: All Other HVAC Questions
- Topic: Thermostat heat anticipator setting?
- Replies: 3
- Views: 5090
Thermostat heat anticipator setting?
What is a good setting for the heat anticipator? Is there any rule of thumb for where it should be set or is it kinda of wing it thing? Thanks :?:
- Mon Dec 01, 2008 9:02 pm
- Forum: Nordyne Service & Repair
- Topic: Intertherm M1MB 07A BW lighting problem
- Replies: 1
- Views: 1605
Intertherm M1MB 07A BW lighting problem
Model # M1MB 07A BW. SERIAL #M1M981001373. Sometimes when it kicks on it will click and wont light but then it will finally light. I just replaced the ignitor and that didn't help. It is not flashing any codes just steady red light and when it finally lights it also has a yellow light. It doesn't do...
- Sun Feb 03, 2008 10:03 am
- Forum: All Other HVAC Questions
- Topic: Intertherm problem
- Replies: 9
- Views: 5590
RE: Intertherm problem
I would like ordering info and price quote. Thank you Robert.
- Sat Feb 02, 2008 9:02 am
- Forum: All Other HVAC Questions
- Topic: Intertherm problem
- Replies: 9
- Views: 5590
RE: Intertherm problem
Sometimes It flashes sometimes It doesn't. When It does It flashes twice (Open Pressure switch). I replaced the two pieces of tubing awhile back and It seemed to fix It but It still acts up occasionally. It doesn't do this all the time some times It takes right off and works fine. Thank you
- Fri Feb 01, 2008 5:29 pm
- Forum: All Other HVAC Questions
- Topic: Intertherm problem
- Replies: 9
- Views: 5590
RE: Intertherm problem
Model # M1MB 070A BW
SERIAL # M1M98 100 1373
If neither one of these are It could you tell me where to find It. Sorry and thank you.
SERIAL # M1M98 100 1373
If neither one of these are It could you tell me where to find It. Sorry and thank you.