Search found 23 matches
- Wed May 11, 2011 10:39 pm
- Forum: Coleman Service & Repair
- Topic: ac stopped working
- Replies: 2
- Views: 2239
Re: ac stopped working
hi, First thing is double ckeck and make sure ur t-sat is set for cool and fan swith is set for auto. Have u done any mowing or used a weed eater recently, if so, check very carefully the small diameter wire that looks like t-stat wire its usually brown, for any cuts on it. If u find any. shut off p...
- Wed Dec 01, 2010 8:39 pm
- Forum: Coleman Service & Repair
- Topic: low flame
- Replies: 2
- Views: 1766
Re: low flame
Flame being smaller can be caused by a blockage in burner tube , gas valve, gas line, low gas pressure, gas valve going bad, ect. What do you mean by wont heat up house, do you mean it wont reach temp srtting on t-stat, wont ignite, low or no airflow from vents, some vents have airflow, can u be mor...
- Tue Nov 30, 2010 8:21 pm
- Forum: Coleman Service & Repair
- Topic: burner and pilot blow out
- Replies: 4
- Views: 2041
Re: burner and pilot blow out
ck roof jack for seperation, flame should be blue. does pilot stay lite after u light it, w/o out going out. If so, when blower kicks on does the flame move alot. its possible u may have a spider web in the pilot tube/ burner or even in the spud behing the gas valve. Let me know what the flame does ...
- Tue Nov 30, 2010 8:06 pm
- Forum: Coleman Service & Repair
- Topic: Coleman presidential model 7663
- Replies: 3
- Views: 3163
Re: Coleman presidential model 7663
part # 621486. I recommend u purchase it from this site. I'm curious as to why u think u need one. If infact you know for sure that u need one, and found the reason ( short the secondary system, i. e. t-stat wires, ect.) and fixed the problem, I suggest you put a 3 amp " auto" ATC fuse inl...
- Tue Nov 30, 2010 11:50 am
- Forum: Nordyne Service & Repair
- Topic: Freezing. Dont know what to do??
- Replies: 2
- Views: 2066
Re: Freezing. Dont know what to do??
Can u post more info on your unit, I'm coming up with an a/c using that model number. Its possible that the database I am currentley using is wrong. Is this a pilot lite , hsi, extra. Are u sure the model u gave is for the furnace and not the a/c part. Like I said I could be off track here. U might ...
- Mon Nov 29, 2010 9:43 pm
- Forum: Nordyne Service & Repair
- Topic: Heats poorly
- Replies: 4
- Views: 2781
Re: Heats poorly
Based on your post it could be a number of things including a problem with a heating element, a bad sequencer or one going bad, an open limit to a element, ect. First thing is check all circuit breakers. Before we go any farther, this furnace involves HIGH VOLTAGE 220V. This is extremely dangerous. ...
- Sat Oct 30, 2010 8:42 pm
- Forum: Coleman Service & Repair
- Topic: coleman dgat070bdf kept flashin once now keeps blowing fuse.
- Replies: 4
- Views: 2221
Re: coleman dgat070bdf kept flashin once now keeps blowing f
Hi,
This something that should be addressed by a technician. Some3thing is definitely shorting out.
The breaker tripping is a safety net. Dont keep flipping the breaker on. This unit should not be operated till its fixed. U have a baby, do u both a favor and get it fixed right.
This something that should be addressed by a technician. Some3thing is definitely shorting out.
The breaker tripping is a safety net. Dont keep flipping the breaker on. This unit should not be operated till its fixed. U have a baby, do u both a favor and get it fixed right.
- Sat Oct 30, 2010 8:36 pm
- Forum: Coleman Service & Repair
- Topic: BGU07516A FOUR FLASHING LIGHTS
- Replies: 2
- Views: 1851
Re: BGU07516A FOUR FLASHING LIGHTS
Vacuuming it out and changing the filter is a good start. Don't take this wrong, but how long was it prior to this change did u last change filter, if it was quite awhile, or its been awhile since a tune up was done, the blower wheel could be dirty. usually when a unit goes off on limit, its because...
- Sat Oct 30, 2010 8:10 pm
- Forum: Coleman Service & Repair
- Topic: Coleman Evcon Wont ignite
- Replies: 10
- Views: 3946
Re: Coleman Evcon Wont ignite
hi, there u say u have 24v at W board terminal, but zero at C. i believe Robert wants u to place 1 meter probe on the W terminal on the board and the other meter probe on the C board terminal and ck for 24v. i am curious as to where u put meter probes an got 24v at w terminal and 0 at C terminal. ma...
- Sat Oct 23, 2010 1:29 pm
- Forum: Nordyne Service & Repair
- Topic: M1MB 070A BW Ignition parts/a little help
- Replies: 9
- Views: 4401
Re: M1MB 070A BW Ignition parts/a little help
As a suggestion, u might have better luck using a couple of large cresent wrenches or better pipe wrenches
- Sat Oct 23, 2010 1:23 pm
- Forum: Nordyne Service & Repair
- Topic: cmf 80 code 3
- Replies: 2
- Views: 3975
Re: cmf 80 code 3
I'm not completely familiar with this unit, however,u said it ignites for a few seconds, do u mean the ignitor just glows or do u have flame? If u have flame, it sounds like the flame sensor is not detecting the flame. If this is the case u can use a piece of LIGHT sand paper or a green kitchen scra...
- Sat Oct 23, 2010 1:05 pm
- Forum: Nordyne Service & Repair
- Topic: Intertherm MGHA-090
- Replies: 3
- Views: 2184
Re: Intertherm MGHA-090
the most likely cause based on your description is a faulty fan switch
the can be ordered from this site at a reasonably cost.
remember to turn power to the unit off, before disconnecting/reconnecting the fan switch.
go to the parts section of this site
the can be ordered from this site at a reasonably cost.
remember to turn power to the unit off, before disconnecting/reconnecting the fan switch.
go to the parts section of this site
- Tue Sep 21, 2010 8:19 pm
- Forum: Nordyne Service & Repair
- Topic: MGH-075 Intertherm
- Replies: 2
- Views: 3556
Re: MGH-075 Intertherm
Its possible the high limit switch is bad. The fan switch could be faulty. Does this unit have an a/c box, if so is the t-stat 2 wire or 5. Its been awhile since i worked on one. One of the moderators. a gentleman by the name of Robert, is an expert here, u might be better off waiting for his reply,...
- Tue Sep 21, 2010 8:11 pm
- Forum: Coleman Service & Repair
- Topic: Older 7900 series blower problem
- Replies: 10
- Views: 4310
Re: Older 7900 series blower problem
If you wired it up correctly, which appears to be the case, Its possible that u got a bad motor, however, its more likely u have a bad capacitor. Is the cap buldging or in anyway disformed? Check and make sure the capacitor wires are still connected securely, I have ran into a situation where anothe...
- Fri Aug 13, 2010 7:46 pm
- Forum: Nordyne Service & Repair
- Topic: Air conditioner blowing warm air
- Replies: 4
- Views: 2642
Re: Air conditioner blowing warm air
U either have a weak/loose breaker or something is drawing to much current. How much experience do u have with a DVM meter? If u dont have alot of experience, its best to call a pro. U can start by shutting off the power to the outside unit and checking to see if every electrical connection is tight...