Search found 9 matches

by gamorrow
Fri Dec 17, 2010 8:02 am
Forum: Coleman Service & Repair
Topic: 1995 Coleman EB17B-24V not always at T-stat
Replies: 1
Views: 1455

1995 Coleman EB17B-24V not always at T-stat

Morning...noticed that heating Elements are working, but the fan motor is not turning on. I go to the Thermostat and move the contact lever up and down and there is no spark when the contacts meet. When I go through moving the wiring around and pulling on and off the wires to their connectors...then...
by gamorrow
Mon Oct 18, 2010 7:06 am
Forum: Coleman Service & Repair
Topic: one of three coils has 240 volts
Replies: 5
Views: 2432

Re: one of three coils has 240 volts

Thank you Robert...I will be ordering the sequencer and limits soon. Have a good day...God bless you.
by gamorrow
Sun Oct 17, 2010 8:36 am
Forum: Coleman Service & Repair
Topic: one of three coils has 240 volts
Replies: 5
Views: 2432

Re: EB17B...one of three coils has 240 volts

Robert...what part number is for a limit switch...that is used in a EB17B furnace that uses a 3115-357 sequencer? The limit switches are used on heating element packages Part numbers 3500-412, and 3500-405. The limiters in this furnace is made of a white ceramic material, and are held down by only O...
by gamorrow
Sat Oct 16, 2010 8:06 am
Forum: Coleman Service & Repair
Topic: one of three coils has 240 volts
Replies: 5
Views: 2432

one of three coils has 240 volts

Good morning from Dahlonega, Ga....I have a 1995 EB17 with 240v output on both breakers, and all three heating coils read the same low ohms...however, only one (1) coil out of three (3) has 240 volts at the coils...whatcha think? Went back and checked the ohms across the coil contacts where the wire...
by gamorrow
Fri Jan 01, 2010 7:26 am
Forum: Coleman Service & Repair
Topic: Does Coleman EB17B Furnace have a Blower Fan Relay?
Replies: 3
Views: 1499

Re: Does Coleman EB17B Furnace have a Blower Fan Relay?

Thanks Robert--Humbly Grateful...have a wonderful and blessed new year and may God watch over and protect your family.
by gamorrow
Thu Dec 31, 2009 4:18 pm
Forum: Coleman Service & Repair
Topic: Does Coleman EB17B Furnace have a Blower Fan Relay?
Replies: 3
Views: 1499

Does Coleman EB17B Furnace have a Blower Fan Relay?

Does the EB17B Furnace have a Blower Fan Relay and if it does, where is it located on the furnace?
by gamorrow
Thu Dec 31, 2009 3:59 pm
Forum: Coleman Service & Repair
Topic: Coleman EB17B THERM OFF BUT HEAT ELEMENTS ON ALWAYS
Replies: 2
Views: 1431

Re: Coleman EB17B THERM OFF BUT HEAT ELEMENTS ON ALWAYS

Just found the problem...I looked over the Lower Control Board 7681-317P, and I spotted a loose resistor joint where the solder meets the resistor lead. Resoldered the loose joint and the unit is working fine again.
by gamorrow
Thu Dec 31, 2009 2:09 pm
Forum: Coleman Service & Repair
Topic: Coleman EB17B THERM OFF BUT HEAT ELEMENTS ON ALWAYS
Replies: 2
Views: 1431

Coleman EB17B THERM OFF BUT HEAT ELEMENTS ON ALWAYS

Just started last night-- woke this morning to a cold home...went to the furnace and it was warm standing by the unit...opened unit...hot around heating elements and sheet metal, but no running fan. Went to the thermostat and rocked the control arm up-and-down several times listening to the clicks.....
by gamorrow
Mon Oct 12, 2009 7:50 am
Forum: Coleman Service & Repair
Topic: Part #7681-317P , F7454
Replies: 1
Views: 888

Part #7681-317P , F7454

Does any one know what type of 18 pin, U1 integrated circuit (ic) is used on this Coleman Lower Control Board? I have a blown chip and I believe if I replace this chip, my problem might be solved.