Re: Whooshing noise and plentum is not heating up-inconsista
If anyone else is wondering, this is a reply I got elsewhere on this issue. Hope it helps someone out there! What you are probably hearing is the LP burning inside of the burner tube venturi, instead of on top where it should be. The bang ba-woosh is delayed ignition, where gas builds up and ignites...
- Thu Nov 19, 2015 5:14 pm
- Forum: Coleman Service & Repair
- Topic: Whooshing noise and plentum is not heating up-inconsistant
- Replies: 2
- Views: 20265
Re: Whooshing noise and plentum is not heating up-inconsista
The furnace is propane.
- Wed Nov 18, 2015 5:58 pm
- Forum: Coleman Service & Repair
- Topic: Whooshing noise and plentum is not heating up-inconsistant
- Replies: 2
- Views: 20265
Whooshing noise and plentum is not heating up-inconsistant
Coleman Presidential 3 7966-856 Pilot light is a 50% yellow and 50% blue, does not hardly move when blower is on. When the Thermostat calls for heat, it does this every so often: woshwoshshshshshshshshshshshhshsh, while it makes this noise, the burner is lit, but the plenum is not heating up to temp...