Search found 6 matches
- Tue Nov 02, 2010 12:44 pm
- Forum: Coleman Service & Repair
- Topic: Coleman 7966A396 No power
- Replies: 2
- Views: 1490
Re: Coleman 7966A396 No power
Found problem with circuit breaker!!!! Didn't look tripped but I switched it off then on and now it works. CB will be replaced.
- Tue Nov 02, 2010 11:59 am
- Forum: Coleman Service & Repair
- Topic: Coleman 7966A396 No power
- Replies: 2
- Views: 1490
Coleman 7966A396 No power
I replaced the fan last Jan. and the heater worked fine up until I shut it down. The pilot is lit but furnace appears to have no power at all. There is a control panel about halfway up inside with a single swithc that is on and I recall hearing a slight humming when it was working but now nothing. N...
- Tue Jan 12, 2010 3:07 pm
- Forum: Coleman Service & Repair
- Topic: Coleman Heater 7966A856 Blower Motor Hot
- Replies: 2
- Views: 1734
Re: Coleman Heater 7966A856 Blower Motor Hot
After looking at the furnace I've concluded that the motor is operating normally. With the furnace off the motor is at room temp. After the furnace runs and shuts off the motor immediatley feels cool due to the volume of air flow but then heats up to considerably before a gradual cool down. I'm goin...
- Tue Jan 12, 2010 10:26 am
- Forum: Coleman Service & Repair
- Topic: Coleman Heater 7966A856 Blower Motor Hot
- Replies: 2
- Views: 1734
Coleman Heater 7966A856 Blower Motor Hot
I replaced the blower motor last week (7966-311P Blower Motor). Hook up was straight forward but now with the furnace on (normalized) thermostat not engaged the motor is hot to the touch. Limit switch is OK. With the furnace running the motor is cool to the touch due to the volume of air flowing by ...
- Tue Jan 05, 2010 7:30 pm
- Forum: Coleman Service & Repair
- Topic: Coleman Heater 7966-856 Blower Motor Installation Question
- Replies: 2
- Views: 1623
Re: Coleman Heater 7966-856 Blower Motor Installation Question
I figured out I only had to remove the front screws and screws on the left and the whole assy. slid oud. I was able to find a replacement motor locally and made the repair myself. The article on blower assy maintenance was most helpful!
- Sun Jan 03, 2010 10:02 pm
- Forum: Coleman Service & Repair
- Topic: Coleman Heater 7966-856 Blower Motor Installation Question
- Replies: 2
- Views: 1623
Coleman Heater 7966-856 Blower Motor Installation Question
I have a Coleman 7966-856 60K In / 53K Out. Blower motor is obviously bad since there's a high pitch squeal and cage is slow to turn and reset switch will trip when it tries to run. Looks like the motor is a 7966-311 model. How difficult is it to remove the blower assy to remove the motor? After dis...