Search found 4 matches
- Tue Feb 16, 2010 10:51 pm
- Forum: Nordyne Service & Repair
- Topic: M1BB 086A BW gas furnace Wont Start
- Replies: 5
- Views: 2733
Re: M1BB 086A BW gas furnace Wont Start
i got my tester back frm my buddy and tested everything, turned out to be the centrifical switch in the motor shorted so I had to get a new motor, motor would run when I bypassed the modul thou so it was just the switch coming from the module, thanks anyways. Odd thing is the short blew the fuse but...
- Mon Feb 15, 2010 9:13 am
- Forum: Nordyne Service & Repair
- Topic: M1BB 086A BW gas furnace Wont Start
- Replies: 5
- Views: 2733
Re: M1BB 086A BW gas furnace Wont Start
any deas?
- Sun Feb 14, 2010 12:06 pm
- Forum: Nordyne Service & Repair
- Topic: M1BB 086A BW gas furnace Wont Start
- Replies: 5
- Views: 2733
Re: M1BB 086A BW gas furnace Wont Start
After taking the cover off where the coil and transformer are I found the 3a fuse on the red wire going coming from the thermastat to the transformer was blown, changed it turned power on and the thermastat made a cranckling noise like it fried itself and the fuse didnt blow but got very warm and th...
- Sun Feb 14, 2010 10:25 am
- Forum: Nordyne Service & Repair
- Topic: M1BB 086A BW gas furnace Wont Start
- Replies: 5
- Views: 2733
M1BB 086A BW gas furnace Wont Start
Miller/nordyne M1BB 086A BW
Turn termostat on and nothing happens, power to the furnace but no noises f anythign trying to start and no led lights on the UE 1018 hot surface ignightor which should be flashing something. Tells me the board must be bad
what are your thoughts???
Thanks
Dana
Turn termostat on and nothing happens, power to the furnace but no noises f anythign trying to start and no led lights on the UE 1018 hot surface ignightor which should be flashing something. Tells me the board must be bad
what are your thoughts???
Thanks
Dana