Intertherm motor problem
Robert & Mark & the rest of your staff. I just wanted to thank you all for helping me out getting me the right motor & capacitor & belly band for my unit. It is sooo much quieter now & my wife hugged my neck for fixing it right the first time w/out burning it up. It starts in low now & then goes into high like its suppost to. I went to theEmerson website & posted a comment about getting my warr. activated& hope to hear from them soon. There was no warr. papers in the box to fill out & send in. Again thanks to all & God Bless you all. David!! Man! it soo much more peacefull around here.
I am a certified ford diesel tech, "Retired Now" Ford Parts Department counter man, computer consultant, repairman & programmer
Hi David,
You're very welcome, happy to help. You can call Mark toll free at
1-877-263-7860 and he can answer any warranty questions for
you.
Time to take your bride out for a good meal, you've both earned it.
Take care and best wishes,
Robert
You're very welcome, happy to help. You can call Mark toll free at
1-877-263-7860 and he can answer any warranty questions for
you.
Time to take your bride out for a good meal, you've both earned it.
![Smile :)](./images/smilies/icon_smile.gif)
Take care and best wishes,
Robert
Some people are Humbly Grateful, while some are Grumbly Hateful.................... Which one are you ?
![Very Happy :D](./images/smilies/icon_biggrin.gif)
![Smile :)](./images/smilies/icon_smile.gif)
I am a certified ford diesel tech, "Retired Now" Ford Parts Department counter man, computer consultant, repairman & programmer
Hi David,
Are you asking where to attach the green ground wire from new motor ?
If so, it attaches to the outside of the blower housing.
Usually can place it under one of the screws holding the run cap to side of housing.
Thanks,
Robert
Are you asking where to attach the green ground wire from new motor ?
If so, it attaches to the outside of the blower housing.
Usually can place it under one of the screws holding the run cap to side of housing.
Thanks,
Robert
Some people are Humbly Grateful, while some are Grumbly Hateful.................... Which one are you ?
![Smile :)](./images/smilies/icon_smile.gif)
![Wink :wink:](./images/smilies/icon_wink.gif)
I am a certified ford diesel tech, "Retired Now" Ford Parts Department counter man, computer consultant, repairman & programmer
Hi David,
Just use the wires from new motor. Most furnaces use High for a/c and for continous on.
Low or med. low for heat.
May want to change the manual switch set up to go through same circuit as a/c for high speed.
The small green under screw for run cap strap on side of blower housing assembly.
Thanks,
Robert
Just use the wires from new motor. Most furnaces use High for a/c and for continous on.
Low or med. low for heat.
May want to change the manual switch set up to go through same circuit as a/c for high speed.
The small green under screw for run cap strap on side of blower housing assembly.
Thanks,
Robert
Some people are Humbly Grateful, while some are Grumbly Hateful.................... Which one are you ?
![Smile :)](./images/smilies/icon_smile.gif)
![Very Happy :D](./images/smilies/icon_biggrin.gif)
I am a certified ford diesel tech, "Retired Now" Ford Parts Department counter man, computer consultant, repairman & programmer
![Smile :)](./images/smilies/icon_smile.gif)
![Very Happy :D](./images/smilies/icon_biggrin.gif)
I am a certified ford diesel tech, "Retired Now" Ford Parts Department counter man, computer consultant, repairman & programmer
Hi David,
On behalf of mobilehomerepair.com, thank you for the kind words and support and you're very welcome.
Take care and best wishes,
Robert
On behalf of mobilehomerepair.com, thank you for the kind words and support and you're very welcome.
Take care and best wishes,
Robert
Some people are Humbly Grateful, while some are Grumbly Hateful.................... Which one are you ?
Hey Robert! I have a question about setting my Hunter digital nonprogrammable thermostat to a comfortable setting so our electric bill won't be so high in 100 degree outside temps. Next week is going to be up into the over 100 degree temps. My wife has to keep it so cold in our house & sets it to 70-72 degrees & I keep resetting it to 75 degrees which I know that makes the bill higher resetting it all the time.I was also told NOT to block off any registers in the house cause it can make the unit work harder & possibly burn up the motor. We have 4 registers in our house. Where can I purchase 4 new 4"x 8" brown floor registers? Mine are all broken. I have a tendency to block off mine in my computer room to keep from freezing to death. By the way, the new motor is working fine so far. Thanks for all the support you provided in the past. David
I am a certified ford diesel tech, "Retired Now" Ford Parts Department counter man, computer consultant, repairman & programmer
Hi David,
If the temps are over 100, then trying to get home down to 70/72 is not likely, unless your home is super well insulated with top windows, doors, lots of shade, etc... .
Even then it would be hard.
I would put it around 73* (middle ground) and leave it there.
Use ceiling fans to help circulate air, insulated curtains closed on sunny side of home, etc.
You can close a register for temporary time only, but best to only close half way or so.
You can call Mark toll free at 1-877-263-7860 to order the register grilles.
He will be back in office by Monday or Tuesday from a short vacation.
Take care and best wishes,
Robert
If the temps are over 100, then trying to get home down to 70/72 is not likely, unless your home is super well insulated with top windows, doors, lots of shade, etc... .
Even then it would be hard.
I would put it around 73* (middle ground) and leave it there.
Use ceiling fans to help circulate air, insulated curtains closed on sunny side of home, etc.
You can close a register for temporary time only, but best to only close half way or so.
You can call Mark toll free at 1-877-263-7860 to order the register grilles.
He will be back in office by Monday or Tuesday from a short vacation.
Take care and best wishes,
Robert
Some people are Humbly Grateful, while some are Grumbly Hateful.................... Which one are you ?
![Wink :wink:](./images/smilies/icon_wink.gif)
![Crying or Very sad :cry:](./images/smilies/icon_cry.gif)
I am a certified ford diesel tech, "Retired Now" Ford Parts Department counter man, computer consultant, repairman & programmer
Hi David,
You're very welcome, happy to help. Please accept my family and the family of mobilehomerepair.com condolences in the loss of your son.
So saddenned to hear this news and wish you and your wife comfort at this time.
Take care and God Bless,
Robert
You're very welcome, happy to help. Please accept my family and the family of mobilehomerepair.com condolences in the loss of your son.
So saddenned to hear this news and wish you and your wife comfort at this time.
Take care and God Bless,
Robert
Some people are Humbly Grateful, while some are Grumbly Hateful.................... Which one are you ?
-
- Similar Topics
- Replies
- Views
- Last post
-
- 2 Replies
- 60322 Views
-
Last post by jazsimpson
Sat Jul 08, 2017 8:16 am
-
- 0 Replies
- 25774 Views
-
Last post by Tonystark
Fri Dec 07, 2018 12:30 pm
-
-
intertherm standing pilot propane burner Heat Rise of 38°F spread.
by justplumducky » Fri Aug 25, 2017 10:06 am » in Nordyne Service & Repair - 0 Replies
- 55150 Views
-
Last post by justplumducky
Fri Aug 25, 2017 10:06 am
-
-
-
Intertherm standing pilot LPG burner 77 BTU IN gas valve mounting plate gets hot ( not warm).
by justplumducky » Sat Sep 09, 2017 3:34 am » in Nordyne Service & Repair - 1 Replies
- 74921 Views
-
Last post by Maxwell.lipphardt
Thu Nov 22, 2018 10:15 am
-
-
-
Intertherm outdoor a/c unit, blower not turning off. Model unknown rating plate is faded out.
by tkrueger » Sat May 05, 2018 8:57 pm » in Nordyne Service & Repair - 0 Replies
- 116483 Views
-
Last post by tkrueger
Sat May 05, 2018 8:57 pm
-