Coleman electric furnace
I have A coleman electric furnace (model EB12B)that blows heat sometimes and at other times blows cold.Last year I bought (from you guys )the whole coils and limit assembly and it worked.Now this year it started doing the same thing as before replacing the coils and limits. Now could this be the sequencer or something else. Before it would get lot colder than it dose now.I can set it on 68and it will be 60.Sometimes works fine when it dose start blowing cold I can trip the breaker and it starts blowing hot.
Hi,
Probably a bad sequencer.
Sequencer # 3110 - 3571 can be seen and ordered through PayPal from left side here :
http://www.mobilehomerepair.com/ColemanElec.html
Thanks,
Robert
Probably a bad sequencer.
Sequencer # 3110 - 3571 can be seen and ordered through PayPal from left side here :
http://www.mobilehomerepair.com/ColemanElec.html
Thanks,
Robert
Some people are Humbly Grateful, while some are Grumbly Hateful.................... Which one are you ?
-
- Similar Topics
- Replies
- Views
- Last post
-
- 3 Replies
- 37390 Views
-
Last post by David DeBord
Sun Oct 22, 2017 8:16 am
-
-
Electric water heater, standard VS. MH specific
by ferret13sj » Thu Aug 26, 2021 3:41 am » in Mobile Home Repair - 4 Replies
- 49392 Views
-
Last post by Sulteric
Sun Sep 05, 2021 9:39 pm
-
-
-
Eb12eb Coleman furnace 4 speed help.
by Johnwayne892000 » Thu Aug 30, 2018 7:37 pm » in Coleman Service & Repair - 0 Replies
- 25001 Views
-
Last post by Johnwayne892000
Thu Aug 30, 2018 7:37 pm
-
-
-
Coleman 6806a furnace doesn't stop heating even with tstat disconnected. Any ideas?
by Neighbor Bill » Mon Dec 31, 2018 1:01 pm » in Coleman Service & Repair - 1 Replies
- 41721 Views
-
Last post by Neighbor Bill
Mon Dec 31, 2018 1:06 pm
-
-
-
DGAT Series furnace air-conditioning issue
by minnie1967 » Thu Jul 13, 2017 9:48 am » in Coleman Service & Repair - 0 Replies
- 61936 Views
-
Last post by minnie1967
Thu Jul 13, 2017 9:48 am
-