my nordyne heater was not putting out any heat. found elements were no good. replaced all of them. now elements dont cut off. turned off breakers took out little round switch on bottom set of elements. didnt see anything wrong visually. put it back in. no elements are kicking off an on all the time every few seconds. could it be a sequencer or the round switch i pulled out. could they be bad. how can i tell which it is. switch or sequencer. please help. have a great day
model number of heater is e2eh-015 i think that is right
help with nordyne heater
Hi,
Most likely the sequencer.
Sequencer # 01-0842 can be seen and ordered through PayPal from left side of this page:
http://www.mobilehomerepair.com/NordyneElec.html
Thanks,
Robert
Most likely the sequencer.
Sequencer # 01-0842 can be seen and ordered through PayPal from left side of this page:
http://www.mobilehomerepair.com/NordyneElec.html
Thanks,
Robert
Some people are Humbly Grateful, while some are Grumbly Hateful.................... Which one are you ?
-
- Similar Topics
- Replies
- Views
- Last post
-
-
Help with Nordyne electronic board
by swade1991 » Thu Aug 02, 2018 12:13 pm » in Nordyne Service & Repair - 0 Replies
- 33091 Views
-
Last post by swade1991
Thu Aug 02, 2018 12:13 pm
-
-
-
G.E.supplemental coil heater in wall unit
by stevenbrooks » Mon Jul 17, 2017 4:00 pm » in Service & Repair of Other Brands - 0 Replies
- 38685 Views
-
Last post by stevenbrooks
Mon Jul 17, 2017 4:00 pm
-
-
-
I am thinking of switching to a gas water heater
by deryk the gypsy » Sat Jul 22, 2017 7:16 am » in Mobile Home Repair - 2 Replies
- 39199 Views
-
Last post by Greg
Sat Jul 22, 2017 12:26 pm
-
-
-
Propane wall heater flickers badly
by nestsman » Tue Nov 28, 2017 1:23 pm » in Service & Repair of Other Brands - 2 Replies
- 33919 Views
-
Last post by suzy_dickson
Fri Jul 05, 2019 12:54 am
-
-
- 3 Replies
- 21283 Views
-
Last post by Greg
Sun Feb 25, 2018 9:49 am