hello and thanks for this forum.
ive searched this forum, but didnt find exactly
an answer to my delimma.
i had to buy a new blower motor for my coleman furnace model
3400-815.
the new motor is 1468-120p rated 1/6 hp 230 volts and is 2 speed.
(im guessing the 2 speeds are 1050 rpm and 900 rpm)
and has 4 wires...2 black, 1 red, and one orange.
my problem is that the motor i am repacing
(3400-a123 which i believe was not original as my
parts list the motor as being a 3400-590)
has only 2 wires 1 black and 1 faded yellow.
this motor was a single speed, 1/8 hp, 230 volts with 810 rpm.
now my question is how to wire the new motor to the molex
to replace just 2 prior wires?
i hope you can understand and i would greatly appreciate
any help in this matter.
..and happy holidays.
coleman furnace 3400-815 motor
Hi,
Red is 120vac low speed. Connect to black.
Orange is the neutral wire. Connect to faded yellow .
Thanks,
Robert
Red is 120vac low speed. Connect to black.
Orange is the neutral wire. Connect to faded yellow .
Thanks,
Robert
Some people are Humbly Grateful, while some are Grumbly Hateful.................... Which one are you ?
-
- Posts: 2
- Joined: Wed Dec 22, 2010 9:15 pm
thank you so much for the quick reply....now i will have a white xmas with warmth.
You're very welcome, happy to help. There saying we may have a white Christmas as well.
Take care and best wishes,
Robert
Take care and best wishes,
Robert
Some people are Humbly Grateful, while some are Grumbly Hateful.................... Which one are you ?
-
- Similar Topics
- Replies
- Views
- Last post
-
- 2 Replies
- 60298 Views
-
Last post by jazsimpson
Sat Jul 08, 2017 8:16 am
-
- 0 Replies
- 25767 Views
-
Last post by Tonystark
Fri Dec 07, 2018 12:30 pm
-
-
Eb12eb Coleman furnace 4 speed help.
by Johnwayne892000 » Thu Aug 30, 2018 7:37 pm » in Coleman Service & Repair - 0 Replies
- 24988 Views
-
Last post by Johnwayne892000
Thu Aug 30, 2018 7:37 pm
-
-
-
Coleman 6806a furnace doesn't stop heating even with tstat disconnected. Any ideas?
by Neighbor Bill » Mon Dec 31, 2018 1:01 pm » in Coleman Service & Repair - 1 Replies
- 41711 Views
-
Last post by Neighbor Bill
Mon Dec 31, 2018 1:06 pm
-
-
-
DGAT Series furnace air-conditioning issue
by minnie1967 » Thu Jul 13, 2017 9:48 am » in Coleman Service & Repair - 0 Replies
- 61916 Views
-
Last post by minnie1967
Thu Jul 13, 2017 9:48 am
-