coleman model DGAA070BDTA
-
- Posts: 2
- Joined: Sun May 22, 2011 12:12 pm
i cant get AC UNIT TO WORK ON AUTO to even get it to come on i have to play with the ventalation switch it the blower comes on but then shuts off after 30 seconds after playing with it finally come on but will shut off when i switch it to auto the ac unit continues to run so i have too turn it off once home gets cool then retart it when it gets hot inside could it be the thermostat or do i need to shell out a couple hundred bucks for a new control board???
Hi, It sounds to me like its the thermostat. The easiest way to check that is to try and jump the a/c at the control board in the furnace and see if it comes on. If it does then i would start with a new stat.
Thanks,
Bill
Thanks,
Bill
Please remember to check and change your filters.
-
- Similar Topics
- Replies
- Views
- Last post
-
-
Model DGAA070BDTA venting kit needed.
by spazatac » Fri May 24, 2024 11:21 am » in Coleman Service & Repair - 2 Replies
- 703 Views
-
Last post by spazatac
Mon Jun 10, 2024 3:11 pm
-
-
-
Intertherm outdoor a/c unit, blower not turning off. Model unknown rating plate is faded out.
by tkrueger » Sat May 05, 2018 8:57 pm » in Nordyne Service & Repair - 0 Replies
- 116444 Views
-
Last post by tkrueger
Sat May 05, 2018 8:57 pm
-
-
-
Nordyne model m1mb 070a bw power issue
by Combustibleink » Mon Nov 16, 2020 10:21 am » in Nordyne Service & Repair - 0 Replies
- 116111 Views
-
Last post by Combustibleink
Mon Nov 16, 2020 10:21 am
-
-
-
Evcon Heat Pump - Air Conditioner Model No. BRHS036B Making HUM Before Starting
by Dave_L » Tue Aug 29, 2023 1:26 am » in Coleman Service & Repair - 0 Replies
- 126535 Views
-
Last post by Dave_L
Tue Aug 29, 2023 1:26 am
-
-
- 2 Replies
- 60298 Views
-
Last post by jazsimpson
Sat Jul 08, 2017 8:16 am